摘要:分析給水泵變頻調(diào)速節(jié)能原理;針對(duì)鍋爐給水泵改由變頻器控制后存在的汽蝕及平衡盤(pán)磨損等問(wèn)題進(jìn)行了深
入的研究,并提出了解決辦法。
關(guān)鍵詞:給水泵 變頻調(diào)速 鍋爐 汽蝕 平衡盤(pán)磨損
[b][align=center]Effect of the Technique of Variable Frequency Governing on Safety Operation of Boiler Feed water Pump
DU Zhao hui1 XU Pei yao2
(1. Power Station , Baoding Petrochemical Plant of SINOPEC Baoding , Hebei 071051)[/align][/b]
Abstract :The energy saving principle of variable frequency governing technique for the boiler feed water pump is discussed. The problems
such as cavitation erosion and the galling of balance disc following with the variable frequency governing technique in the boiler feed water
pump are studied. Finally a suitable solution is provided.
Keywords :feed water pump variable frequency governing boiler cavitation erosion galling of balance disc
保定石油化工廠電站于1997 年對(duì)2 臺(tái)送風(fēng)機(jī)、2 臺(tái)引風(fēng)機(jī)改為變頻控制,經(jīng)過(guò)幾年的運(yùn)行,節(jié)能效果顯著,設(shè)備運(yùn)行情況良好,于是2003 年把型號(hào)為DG46 50 ×12 的2 # 給水泵改為由日本三墾公司生產(chǎn)的IPF160 K變頻器控制。運(yùn)行一段時(shí)間后,節(jié)能效果也很明顯,但先后出現(xiàn)了給水泵輕度汽蝕及平衡盤(pán)嚴(yán)重磨損的問(wèn)題,造成了給水泵事故跳閘1 次,縮短了2 # 給水泵的運(yùn)行周期,影響了設(shè)備的安全運(yùn)行及全廠的安全生產(chǎn),增加了檢修費(fèi)用。經(jīng)過(guò)研究,電站修改了變頻器幾個(gè)不恰當(dāng)?shù)膮?shù),更換了給水泵的平衡盤(pán),使問(wèn)題得到了解決。
1 變頻調(diào)速節(jié)能原理分析
由于許多熱電聯(lián)產(chǎn)機(jī)組都是以熱定電,負(fù)荷隨季節(jié)波動(dòng)很大,而且現(xiàn)在火電機(jī)組調(diào)峰力度加大,機(jī)組的負(fù)荷變化范圍也很大,這些情況都需要實(shí)時(shí)調(diào)節(jié)給水泵的流量。目前調(diào)節(jié)給水泵流量的方式多為在出口端裝設(shè)閥門(mén)的節(jié)流調(diào)節(jié),其實(shí)質(zhì)是通過(guò)改變出口管路上的流動(dòng)損失,改變管路的特性曲線,來(lái)改變水泵的工作點(diǎn)。由于這種調(diào)節(jié)方式多余的流量?jī)H僅是靠調(diào)節(jié)閥節(jié)流調(diào)節(jié),而電動(dòng)機(jī)的輸出功率并沒(méi)有多大改變,浪費(fèi)了大量的電能。
調(diào)速節(jié)能原理可以從以下2 個(gè)方面來(lái)說(shuō)明: